​​​Liao Fan​​
We believe we're a trustworthy professional manufacturer, a reliable faithful partner in your career. 

product

center​​

  

LF838 Molecular sieve 13X

LF838 Molecular sieve 13X

0.00
0.00
  

LF838 Molecular Sieve 13X

1 Use

  LF83is used for purification of air feed gas (removal of H2O, CO2 and acetylene); drying and sulfur removal of natural gas, LPG and liquid hydrocarbons; drying of common gas and water and CO2 removal in production of O2 from air.

2 Regeneration

  LF838 may be regenerated and reused by purging or vacuum at elevated temperature, the degree of regeneration is determined by regenerating temperature and regenerating humidity.

3 Technical parameters

  Technical parameters of LF838 Molecular sieve 13X are seen in Table 1.

Table 1 Technical parameters of LF838 Molecular sieve 13X

Items

Indexes

Exterior

White extrudate

White sphere

Diameter, mm

1.6

3.2

Ф2-4

Ф4-6

Bulk density, kg/m3

600-640

600-640

620-660

630-670

Crushing strength, N >

30

150

50

65

Equilbrium water capacity*, %(wt)

23.0

23.0

23.0

23.0

Water content (when to be delivered), %(wt) <

1.5

1.5

1.5

1.5

Loss of abrasion 

0.1

0.2

0.25

0.1

Molecules adsorbed <

Molecules with effective diameters <10A

Molecules discharged >

Molecules with effective diameters >10A, including4F93N

* Grams of water adsorbed by 100g activated adsorbant under a pressure of 17.5mm mercury column and a temperature of 25℃.

4 Packing and attentions

● Molecular sieve 13X is packed in plastics bags, 25kg/bag, or iron drums, 200L/drum.

● Customized as per customer’s demand.

● Molecular 13X shall be packed in seal, avoiding exposure to air. It shouldn’t be transported together with water, acid or alkali. It should be stored in clean, dry, and ventilated warehouses.